Trouble: Oil leaking out front of barfeed. Cause: A. Air in system: Check oil level.
B. Pressure to high: Max pressure 30 psi
C. Oil Viscosity too low: Replace oilViscosity Check: You Can Now Order a Tester for $35.00 By Calling SPEGO Trouble: Machine tool will not run, barfeed alarm. Cause A. Prox 1 (safety): move guide cover fully forward.
B. Overload on reversing starter tripped: reset
C. SR relay/Prox 1 defective: replaceTrouble: Barfeed vibrating. Cause: A. Vibration, unless excessive, will not harm barfeed or spindle.
B. Bar not straight: replace or lower RPM
C. Hydraulic fluid to light viscosity: replace with ISO 100 or 150.
D. Improper spindle liner size; use correct liner.
E. Barfeed out of alignment: re-align.
F. Bar feeder out of alignment: re-align.Trouble Pusher will not keep up with bar stock. Cause: Speed control not open enough: open CCW.
NOTE: speed control fully open for Z-SORB!!!!
24 Hours per day service assistance from Spego is available by calling 800-527-7346 or you can fill out the form below which will be E-mailed to us. We will respond to you by return E-mail as soon as possible.